Specifications
| Item | Details |
|---|---|
| Brand | Polycab |
| Polycab product code | LVIS09AXSWY2002C400SA001S |
| Polycab type | A2XWY |
| Cores × size | 2 × 400 sq mm |
| Conductor | Stranded compacted sector shaped Aluminium conductor as per IS 8130, class 1&2; this code: class 2 |
| Insulation | Insulated with Cross Linked Polyethylene (XLPE) to IS 7098-1; 2 mm nominal |
| Inner sheath | Extruded inner sheath with PVC Type ST2/FRLS/FR/LSZH |
| Armour | Armoured with Galvanised steel round wire to IS 3975; 2.5 mm wire |
| Outer sheath | Sheathed with Extruded PVC Type ST2/FRLS/FR/LSZH; minimum 2.36 mm |
| Overall diameter | about 51.61 mm |
| Weight | about 4854 kg/km (about 485.4 kg per 100 m) |
| Voltage | 650/1100 V |
| Temperature | Max.: 90°C; short circuit temperature 250°c |
| Bending radius | Fixed installation 12 x Overall diameter (about 619 mm fixed) |
| Core colours | Red and Black |
| Standards | IS 8130:2013, IS 5831:1984, IS 3975:1979, IS 7098-1:1988 |
| Datasheet | Polycab product specification (PDF) |
Also known as: 2C x 400 sqmm, 2 x 400 mm², 2Cx400, A2XWY 2x400, 2 core 400 mm aluminium cable, 400 sqmm 2 core armoured cable, aluminum armored cable, XLPE power cable, LT cable 1.1 kV
Current rating
| How it is laid | Current rating |
|---|---|
| Buried direct in the ground | 487 A |
| In a single-way duct | 412 A |
| In air | 593 A |
From Polycab's specification (IS 3961-6): air 40 °C, ground 30 °C, conductor 90 °C. Derate for hotter locations, grouped cables and long runs; your electrician makes the final choice.
Other sizes in this cable
| Size | Overall dia. (mm) | Weight (kg/km) | Rating |
|---|---|---|---|
| 4 sq mm | 15 | 403 | 38 A |
| 6 sq mm | 16.5 | 465 | 50 A |
| 10 sq mm | 18 | 551 | 64 A |
| 16 sq mm | 17 | 480.16 | 83 A |
| 25 sq mm | 20 | 671.84 | 109 A |
| 35 sq mm | 22 | 775.55 | 133 A |
| 50 sq mm | 24 | 937.97 | 162 A |
| 70 sq mm | 27 | 1186.85 | 204 A |
| 95 sq mm | 28.68 | 1572.78 | 251 A |
| 120 sq mm | 33 | 1849.49 | 287 A |
| 150 sq mm | 36 | 2182.96 | 328 A |
| 185 sq mm | 37.7 | 2597.6 | 379 A |
| 240 sq mm | 45 | 3418.52 | 448 A |
| 300 sq mm | 46.22 | 4019.07 | 513 A |
| 400 sq mm | 51.61 | 4854 | 593 A |
| 500 sq mm | 61.5 | 6517 | 683 A |
| 630 sq mm | 67.5 | 7790 | 784 A |
400 sq mm in other cores
Also available as
- 2 core 400 sq mm, Copper strip armoured (2XFY)
- 2 core 400 sq mm, Copper armoured (2XWY)
- 2 core 400 sq mm, Aluminium strip armoured (A2XFY)
- 2 core 400 sq mm, Copper unarmoured (2XY)
- 2 core 400 sq mm, Aluminium unarmoured (A2XY)
Uses
Armoured XLPE cable for feeders, motor and pump supplies, and runs that are buried, outdoors or exposed to damage. Two cores: phase and neutral, or + and − for DC. Typical uses: main and sub-main feeders, long runs, building and factory supplies, buried or outdoors.
Not sure between armoured and unarmoured? See armoured vs unarmoured cable.
How to order
Add this cable to your quote list, or send the product code and length on WhatsApp. We confirm availability, rate and dispatch, with a GST invoice, and deliver across India.