Use 1.5 sq mm for lights and fans, 2.5 sq mm for sockets, 4 sq mm for ACs, geysers and heavy kitchen points, and 6 or 10 sq mm for the main supply from the meter. Always match the MCB to the wire.
Wire size by circuit
| Wire | Use for | Usual MCB |
|---|---|---|
| 1.5 sq mm | Lights, fans, small loads | 6 A or 10 A |
| 2.5 sq mm | 6 A and 16 A sockets, fridge, washing machine | 16 A |
| 4 sq mm | AC, geyser, induction cooktop, heavy kitchen points | 20 A |
| 6 sq mm | Main supply for a flat or shop, sub-distribution boards | 32 A |
| 10 sq mm | Main supply for a larger house or office | 40 A |
These suit copper house wire run in conduit in a normal home. Long runs, many wires bunched in one conduit, or hot locations need the next size up. Your electrician follows the Indian wiring code (IS 732) and the wire maker's current tables for the final choice.
Colour code
| Colour | Conductor |
|---|---|
| Red, yellow, blue | Phase (single-phase: usually red) |
| Black | Neutral |
| Green or green-yellow | Earth |
Which type of wire?
Choose flame-retardant wire for homes. FR wire resists the spread of fire; FR-LSH also gives less smoke and halogen gas, which helps people escape; HFFR (halogen-free) is used in hospitals, malls and public buildings. Polycab house wires come in 90 m and 180 m coils in every colour.